Legrand UPS 1f / 1f KEOR S 6000VA, on-line, 6000VA / 5400W, 17 minut, RS232, Tower | 310128

Legrand UPS 1f / 1f KEOR S 6000VA, on-line, 6000VA / 5400W, 17 minut, RS232, Tower

Strážny pes - sledovanie produktu




ak cena klesne pod
ak sa pridá darček
ak sa zmení dostupnosť
ak bude posledný kus

2059.00
  • General features- 3kVA to 10KVA Capacity Range- 1 Phase Input / 1 Phase Output- IGBT Inverter- IGBT Rectifier- High Efficiency- Digital Signal Processor (DSP)- High Input Power Factor (PFC)- High Out
zobraziť ďalšie detaily
Tovar aktuálne nie je
možné objednať.
Záruka 2 roky  Kód: 513175
Výrobca:LEGRAND  
Obrázok Legrand UPS 1f  - 310128
 

Legrand UPS 1f / 1f KEOR S 6000VA, on-line, 6000VA / 5400W, 17 minut, RS232, Tower

    Výrobca: LEGRAND
    PN kód:  310128
    General features- 3kVA to 10KVA Capacity Range- 1 Phase Input / 1 Phase Output- IGBT Inverter- IGBT Rectifier- High Efficiency- Digital Signal Processor (DSP)- High Input Power Factor (PFC)- High Output Power Factor- Low Input and Output Total Harmonic Distortion (THD)- Generator Compatible Operation- Standard IP31 Protection for Industrial Applications- On Site Modular Paralleling Capability up to 4 Units (except 3kVA)- Additional External Chargers for Long Back-Up Time Solutions (6-10kVA only)- Availability of Different Communication Types

    Function- User friendly diagnostic- Advanced management and communication- Integrated By-pass for maintenace- LCD display with interactive menu
    .
    Keor S 6000 (310128 – 310129)
    Legrand UPS model Keor S 6000 is an uninterruptible power source with IGBT switching technology, high frequency PWM technology, Double Conversion On-line, with the possibility to have N+X on site modular redundancy up to total 4 units, Rated Power 6 kVA – 5.4 kW.
    The architecture of this UPS means it can be installed in a Tower configuration. Two different models are available as internal configuration; internal battery or input isolation transformer. Addition to these configurations, simultaneous using of both internal and external battery is possible by DC switch protections.Batteries are lead acid, sealed, free maintenance, valve regulated, and arranged, inside the UPS or external battery cabinet. Internal battery configuration is sized to guarantee a minimum uptime of 20 minutes and at 80% of 0, 9PF load.
    The rectifier of the UPS is comprised of a control and regulating circuit (PFC), which, in addition to normal rectifier functions also:• Automatically corrects the power factor of the load to restore it to a value of & gt;0.99 with a load applied at the output at 75% of the rated load;• Supply the inverter without requiring energy from the batteries, even when the mains voltage is very low;• Ensures low total harmonic distortion of the input current without the addition of filters or supplementary parts.
    The bypass circuit is designed and built in compliance with the following:- Electromechanical switch- Command and control logic managed by a microprocessor that:• Automatically transfers the load directly onto the primary mains line without interrupting the power supply if any conditions of overload, over temperature, continuous voltage outside of the tolerances and inverter anomaly arise;• Automatically re-transfers the primary mains line load to an inverter line, without interrupting the power supply, once normal conditions of the load have been restored;• If the primary mains line and the inverter are not synchronised, the bypass must be disabled.
    The inverter of the UPS is comprised of IGBT technology which provides:• Ensures low total harmonic distortion at the output voltage and 0, 9 power factor;• Provides high efficiency with transformerless design;• Supply the load with regulated voltage and frequency.
    A dedicated software of remote monitoring and management, installed on a PC connected to the UPS, allows to check and set all working parameters of Keor S and furthermore, to schedule and program computer remote shutdown. Optional software or Net Interface card (SNMP) allows the multi server shutdown and UPS remote control on the LAN. Also, standard interface board comes with;• RS232 Serial Communication Port• Emergency Power Off (UPS OFF)• Generator Contact (GEN ON)• Smart Slot (for optional SNMP)
    Keor S is managed by a microprocessor and is able to display, on a control panel and LCD screen, the alarms and operating modes described below:• Line Mode, • Backup Mode, • ECO Mode, • Bypass Supply, • Battery Low, • Battery Bad/ Disconnect, • Overload, • Transferring with interruption• UPS Fault normal operation
    It is possible to change output voltage by 220V, 230V, 240V and frequency by 50Hz or 60Hz from front control panel of Keor S 6kVA. Addition to this, Keor S can be used as 50Hz to 60Hz (or vice versa) Frequency Converter with or without batteries as standard.
    Input, Output and Battery connections are hardwired and protected by suitable MCBs.Keor S 6kVA has internal both static bypass and mechanical (maintenance) bypass as standard.
    Backfeed protection provides additional protection at the input in the event of bypass thyristors are short circuited.The internal backfeed protection provides safety when fault situation occurs in static bypass line and prevents upstream energy to the input.
    Keor S 6kVA Static Uninterruptible Power Supply bears the CE marking, pursuant to Directives 73/ 23, 93/ 68, 89/ 336, 92/ 31, 93/ 68, and is designed and built in compliance with the following standards:• EN 62040-1 “General and safety requirements for UPSs used in areas that are accessible to the operator”• EN 62040-2 “Electromagnetic Compatibility requirements (EMC)”• EN 62040-3 “Performance and test method requirements”
    General FeaturesUPS Topology: On line double conversionArchitecture of the UPS: Stand alone, transformerless, On-Site ParallelingIn/ Out phase Configuration: Mono phase-Mono phaseNeutral: Neutral Passing throughSwitching Technology: IGBTBackfeed Protection: Internal, standardOutput wave form on mains operation SinusoidalOutput wave form on battery operation: SinusoidalStandards: EN 62040-1, EN 62040-2, EN 62040-3
    Input FeaturesNominal Voltage: 230 V mono phase + neutral + PEVoltage Range: 195V-280V Ph-N full loadFrequency: 45 - 65HzTHDi: & lt; 7% at full loadPower Factor: & gt; 0.99
    BypassNominal Voltage: 230 V mono phase + neutral + PEVoltage Range: ±10% (adjustable)Frequency: ±3Hz (adjustable)Bypass type: Static and electro-mechanicTransfer time: ZeroManual Bypass: Built-in
    Output with Mains (AC-AC)Nominal Voltage: 220V, 230V, 240V mono phase + neutral + PENominal Power: 6.000 VAActive Power: 5.400 WVoltage variation (static): ± 1%THDv on nominal power (linear load): & lt; 2, 5%Frequency: 50 Hz or 60 Hz (selectable)Frequency tolerance: ± 0, 2% Synchronized with bypass frequencyCurrent Crest Factor: 2, 5:1 accordingly to IEC 62040-3Overload capability:* 2min: 120% load rate with no bypass transfer* 30sec: 150% load rate with no bypass transfer
    Output with Mains (DC-AC)Nominal Voltage: 220V, 230V, 240V mono phase + neutral + PENominal Power: 6.000 VAActive Power: 5.400 WVoltage variation (static): ± 1%THDv on nominal power (linear load): & lt; 2%Frequency: 50 Hz or 60 Hz (selectable)Frequency tolerance: ± 0, 01% free runCurrent Crest Factor: 2, 5:1 accordingly to IEC 62040-3Overload capability:* 2min: 120% load rate* 30sec: 150% load rate
    Battery featuresType: Lead Acid, sealed, maintenance free VRLAInternal Battery Capacity *: 12 Ah (12V)Nominal UPS Battery Voltage: 240 Volt DCMax. number of possible internal battery: 20pcsStandard Charging Current: 1, 6 AAdditional Charger: Yes, Optional - External, mountable on battery cabinetAdditional Charger Capacity: 2, 5A* When used with internal transformer, batteries must be used in separate cabinet
    Environmental SpecificationsNoise level @ 1m: & lt; 52dBAOperating temperature range: from 0°C to +40°CStock temperature range: from -20°C to +50°CHumidity range: 20-95% not condensingProtection degree: IP31
    Manufacturing SpecificationsNet Weight without batteries **: 52 kgNet Weight with Int. Transformer: 100 kgDimensions (WxHxD): 275 x 716 x 776 mmColour: RAL 7016Communication Interface: 1 serial port RS232, 1 smart slot (for optional internal SNMP), 1 EPO, 1 GENSETInput/ Output connections: 1P + N + PEInput/ Output Circuit Breaker: 32A / 32A
    ** Total weight depends on the quantity of the installed batteries according to the required autonomy
    Doba zalohovania pri 80% zatazi: 22 minút



    Najpredávanejší tovar s podobnou cenou:

    - Nezaradené s podobnou cenou ± 20%

    Cenovo podobné Legrand UPS 1f / 1f KEOR S 6000VA, on-line, 6000VA / 5400W, 17 minut, RS232, Tower

      [najžiadanejšie 5]
    Obrázok produktu Legrand UPS  1f / 1f  DAKER DK 10000VA,  BEZ baterii,  Rack 3U /  Tower,  On-Line,  10000Vkód: 484455

    Legrand UPS 1f / 1f DAKER DK 10000VA, BEZ baterii, Rack 3U / Tower, On-Line, 10000V

    Daker DK 10000 – Inverter (310058) The Legrand UPS Daker DK 10000 model is an uninterruptible power source with high frequency PWM technology, Double Conversion On Line, solid neutral, Ra ...

    Obrázok produktu Legrand UPS 1f / 1f DAKER DK 4500VA,  Rack 4U /  Tower,  On-Line,  4500VA  /  4050W ,  RS2kód: 496672

    Legrand UPS 1f / 1f DAKER DK 4500VA, Rack 4U / Tower, On-Line, 4500VA / 4050W , RS2

    Modelový rad UPS DAKER Daker DK –UPS v prevedení tower rack pre umiestnenie do dátových rozvádzačov.Riešenie pre zálohovanie firemných pracovísk a serverov do 10kVA. On-line dvojitá konve ...

    kód: 407819

    EATON 5PX 3000i RT2U Netpack, line-interactiv, display - meranie, rack / tower , 2U

    Akcia na oktober - UPS mesiaca - akciová cena 01.-30.11.2014 Spoločnosť EATON uviedla na trh novú modelovú radu záložných zdrojov EATON 5PX, ktoré sa vyznačujú interaktívnym zálohovaním ...

    Recenzie Legrand UPS 1f


    Legrand UPS 1f / 1f KEOR S 6000VA, on-line, 6000VA / 5400W, 17 minut, RS232, Tower

    Zaradenie tovaru v katalógu:

    Ďalšie podkategórie v skupine :

      PCkonfig.sk  
      PC zostavy PC zostavy