TrippLite SMARTONLINE® Series 1kVA On-Line Double-Conversion UPS, 2U Rack / Tower, 200 /
TrippLite SMARTONLINE® Series 1kVA On-Line Double-Conversion UPS, 2U Rack / Tower, 200 /Výrobca: TRIPP-LITE
PN kód: SUINT1000RTXL2Ua SmartOnline 1kVA On-Line Double-Conversion UPS, 2U Rack/ Tower, 200/ 220/ 230/ 240V C13 outlets
OUTPUT Output Volt Amp Capacity (VA) 1000 Output kVA capacity (kVA) 1 Output Watt Capacity (watts) 800 Output power factor 0.8 Crest Factor 3:1 Nominal Output Voltage(s) Supported 200V; 220V; 230V; 240V Nominal Voltage details 230V default Frequency compatibility 50 / 60 Hz Frequency compatibility details Output frequency matches input nominal on startup, defaults to 50 Hz on cold-start Output voltage regulation (line mode) +/ - 2% Output voltage regulation (Economy line mode) +/ - 10% Output voltage regulation (Battery mode) +/ - 2% Built-in UPS output receptacles 6 C13 outlet(s) Included output power cables Includes 2 C13 to C14 output power cables Output AC waveform (AC mode) Sine wave Output AC waveform (battery mode) Pure Sine wave INPUT Rated input current (at maximum load) 5.1A (200V), 4.9A (208V), 4.6A (220V), 4.4A (230V), 4.2A (240V) Nominal Input Voltage(s) Supported 200V AC; 220V AC; 230V AC; 240V AC UPS input connection type C14 inlet UPS input connection description IEC320-C14 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles Input circuit breaker 8A BATTERY Full load runtime (minutes) 4 min. (800w) Half load runtime (minutes) 12 min. (400w) Expandable battery runtime Extended runtime supported via optional external battery packs External battery pack compatibility BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible) DC system voltage (VDC) 24 Battery recharge rate (included batteries) Less than 6 hours from 10% to 80% Replacement battery cartridge (internal UPS battery replacement) RBC92-2U Battery Access Front panel battery access door Battery replacement description Hot-swappable, user replaceable batteries VOLTAGE REGULATION Voltage regulation description Online, double-conversion power conditioning Overvoltage correction 2% output voltage regulation during overvoltages to 275 Undervoltage correction 2% output voltage regulation during undervoltages to 156 Severe undervoltage correction 2% output voltage regulation during undervoltages to 130 (under 70% load only) LEDS ALARMS & SWITCHES LED Indicators 14 LEDs indicate line power, online mode, economy/ bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/ tower formats Alarms Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions Alarm cancel operation Power-fail alarm can be silenced using alarm-cancel switch Switches 2 Switches control off/ on power status and alarm-cancel/ self-test operation SURGE / NOISE SUPPRESSION UPS AC suppression joule rating 1225 UPS AC suppression response time Instantaneous UPS Dataline suppression 1 line TEL/ DSL (1 in / 1 out); 10/ 100Base T Ethernet EMI / RFI AC noise suppression Yes PHYSICAL Installation form factors supported with included accessories 4 post 19 inch rackmount (mounting rail kit included) Installation form factors supported with optional accessories 2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND) Primary form factor Rackmount UPS / Power Module dimensions in primary form factor (height x width x depth / inches) 3.5 x 17.5 x 13.5 UPS / Power Module dimensions in primary form factor (height x width x depth / cm) 8.9 x 44.4 x 34.3 Installed whole system total rack space height (rack spaces) 2U Secondary form factor Tower (requires 2-9USTAND) UPS / Power Module weight (lbs) 28 UPS / Power Module weight (kg) 12.7 UPS Shipping dimensions (height x width x depth / inches) 8.8 x 23.8 x 20.2 UPS Shipping dimensions (height x width x depth / cm) 22.2 x 60.3 x 51.4 Shipping weight (lbs) 40.3 Shipping weight (kg) 18.3 UPS housing material Steel Cooling method Fan ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 0 to 95%, non-condensing AC mode BTU / hr. (full load) 406.4 AC economy mode BTU / hr. (full load) 173.6 Battery mode BTU / hr. (full load) 442.8 AC economy mode efficiency rating (100% load) 94% COMMUNICATIONS Communications interface USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/ Web interface Network monitoring port description Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications PowerAlert software Included Communications cable USB and DB9 cabling included WatchDog compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer time No transfer time (0 ms.) in online, double-conversion mode Low voltage transfer to battery power (setpoint) 160V (100% load), 130V ( Ďalšie informácie výrobcu: Najpredávanejší tovar s podobnou cenou: Záložne zdroje (UPS) - Záložne zdroje rackové s podobnou cenou ± 20%Cenovo podobné TrippLite SMARTONLINE® Series 1kVA On-Line Double-Conversion UPS, 2U Rack / Tower, 200 /[najžiadanejšie 5]
Recenzie TrippLite SMARTONLINE® Series 1kVA On-Line Double-Conversion UPS |